Autotech M1200 M1200
Resolver‑based die protection and PLS controller with expandable sensors and outputs, plus advanced diagnostics.
Equipment
- Enclosure: 7.6" W × 8.7" H × 5.25" D
- Operating Temp: –10°F to 122°F (–23°C to 50°C)
- Resolver: Autotech E7R / RL100
- Resolver Cable: CBL‑10T22‑Mxxx, up to 2500 ft
Power
- Input: 105–135 VAC, 50/60 Hz, 30 W
Inputs
- Sensors: 4, expandable to 12
- Resolver Input: Yes
- Optical Isolation: 1500 V
- Logic Levels: TRUE < 1.0 VDC @ 7 mA; FALSE 20–24 VDC
- Fault Reset: Resets die protection, brake wear, motion faults
- Program/Supervisor Enable: TRUE allows programming; FALSE view‑only
- Output Enable: TRUE enables outputs; FALSE de‑energizes outputs
- Batch/Quality/Total Reset: Individual inputs reset counters to preset
Outputs
- Fault Output: Detects resolver broken wire and internal faults
- Motion Output: Energized when RPM within programmed limits
- E‑STOP Output: De‑energized on die protection fault
- T‑STOP Output: De‑energized on die protection fault
- Counter Output: De‑energized when Quality Counter = 0
- Relay Type: Electromechanical SPST, 10 A resistive @ 120 VAC
Die Protection & PLS
- Event Detection: Rising, falling, pulse, pos‑hi/pos‑low within window
- Slug Detect Delay: Programmable stroke delays before stop output
- E‑STOP Engagement Angle: 90°–190°; no E‑STOP between engagement and 190°
- Top‑Stop Angle: Programmable angle for T‑STOP
- PLS Outputs: 6 standard, expandable to 14
- PLS Setpoints: 17 per program
- Speed Compensation: Up to 359° per 100 RPM (channels 1–6)
Counters & Memory
- Batch Counter: 6‑digit presettable down; T‑STOP de‑energizes at angle
- Quality Counter: 6‑digit presettable down; output de‑energizes at T‑STOP when 0
- Total Counter: 6‑digit resettable up; resets at power‑up or input
- Tool Counter: 6‑digit tool‑specific up; resettable from keypad
- Programs: 60 setups with 8‑character names; searchable by name
Display & Interface
- Display: 2×20 bright vacuum fluorescent
- Setup: Hot keys, pre‑built sensor name library, custom names