AVG Autotech Controls

Autotech Controls HomeAbout Autotech ControlsSupportDownloadsFree CatalogsContact Autotech Controls

M1250, M1450, and M1451 Mini PLS

1. MINI•PLS System Components
2. MINI•PLS
Select one of the following Single-Turn Rotary PLSs for front panel mounting. Cam modules or power outputs are not included:
SAC-M1250-010 3-Digit, single-turn, basic unit
SAC-M1450-300 3-Digit, single-turn, with ModZ and speed compensation
SAC-M1450-400 4-Digit, single-turn, with ModZ and speed compensation
SAC-M1451-010 3-Digit, single-turn, with ModZ, speed compensation and brake monitor
SAC-M1450-MROF 3-Digit, single-turn with speed compensation and multiple rate offset
1.2 Select one of the following Multi-turn Linear PLS’s for front panel mounting:
Select one of the following Multi-turn Linear PLSs for front panel mounting. Cam modules or power outputs not included:
SAC-M1450-M10 6-Digit, single resolver, semi-absolute, basic unit
SAC-M1450-D64 6-Digit, dual resolver 64:1 ratio, basic unit
SAC-M1450-D128 6-Digit, dual resolver, 128:1 ratio, basic unit
Linear PLS for front-panel mounting. No cam modules or power outputs included:
SAC-1450-LT0 6-Digit, Linear Mini PLS basic unit
*For slave unit, change the A in SAC to S
*For 220/440 VAC 50/60 hz AC power input change the C in SAC to 2
2. Output Modules
Select type and number of optically isolated logic level output cam modules:

ASY-M1250-08TI

TTL outputs, cam module with terminal block

ASY-M1250-08TD

8 TTL outputs, with 15-pin sub D connector

ASY-M1250-08PI

8 PNP outputs, cam module with terminal block

ASY-M1250-08PD

8 PNP outputs, with 15-pin sub D connector

ASY-M1250-08NI

8 NPN outputs, cam module with terminal block

ASY-M1451-LCAMP

Logic Cam output module. Accepts 8 inputs (PNP sourcing) and logic-ANDs each of
the 8 PLS outputs with respective input; has a 9-pin and a 15-pin subD connector for
interconnection. PNP sourcing outputs.
ASY-M1451-LCAMN Logic Cam output module. Accepts 8 inputs (PNP sourcing) and logic-ANDs each of
the 8 PLS outputs with respective input; has a 9-pin and a 15-pin subD connector for
interconnection. PNP sourcing outputs. NPN (sinking) outputs.
Select type and number of optically isolated power output cam modules

ASY-M1250-08AC

8 Output, 120 VAC @ 0.5 A each output, 4 A max. per module, with terminal block

ASY-M1250-08DC

8 Output, 10-28 VDC @ l A each output, 4 A max. per module, with terminal block
Select type and number of special (Position or Tach) modules. (Maximum of two modules from this category may be used in a PLS)
ASY-M1250-20MAP Analog position/tach module; 4-20 mA current PNP (sourcing) sourcing output
ASY-M1250-20MAN Above with current NPN (sinking) output
ASY-M1250-010V Above with 0-10 V analog output
ASY-M1250-X1 X2 X3 Digital position and Tach output modules
    X1 = Output Format:
            BCD: BCD position
            TAC: Digital TACH; BCD output
            GRY: Standard Gray code
    X2 = PC Handshake:  
            1: With PC sync circuit
            0: Without PC sync circuit
    X3 = Output Type:  
            T: TTL with multiplexing
            P: PNP (sourcing) transistor
            N: NPN (sinking) transistor
Select type of serial communication module to be used with SAC-M1450-300 PLS
ASY-M1250-SER2 Bidirectional RS-232C serial communication module
ASY-M1250-SER2L Above module with long-line serial communication
ASY-M1250-SER4 Bidirectional RS-422A serial communication module
Select cable for wiring logic level cam or special modules to external devices (8 outputs per cable):
xxx = length in ft, 010, 025, 050, and 050 ft. increments, e.g., 100, 150, 200 ft., etc.
CBL-09S22-DAxxx 9-conductor, cable with overall foil shield, and 9-pin sub D connector on one end
CBL-15S22-DAxxx 15-conductor, cable with overall foil shield and 15-pin sub D connector on one end
CBL-18S22-Cxxx 18-conductor shielded cable for use with modules with terminal block
ECM-15PIN-M11 15-pin male DSub connector
ECM-09PIN-M11 9-pin male DSub connector
4. Remote Power Relay Output Chassis
Select type and number of output chassis: (must use NPN (sinking)-type output module. Relays not included.
ASY-RLYCH-08RL Chassis for 8 electromechanical SPDT relay outputs (Use with KSD-012DC-10A SPDT relay only)
ASY-RLYCH-16RL Above with 16 electromechanical SPDT relay outputs (Use with KSD-012DC-10A SPDT relay only
ASY-RLYCH-08SS Chassis for 8 solid-state relay outputs or electromechanical SPST outputs using
KSD-A12DC-10A relays
ASY-RLYCH-16SS Above chassis for 16 solid-state relay outputs or electromechanical SPST outputs using
KSD-A12DC-10A relays
    *For 220/240 VAC, 50/60 Hz, AC power input on above chassis, change the Y in "ASY" to 2
Select type and number of output relays: (required in ASY-RLYCH-xxx relay chassis)
KSD-012DC-10A Electromechanical relay, SPDT, Form C, 120 VAC @ l0 A resistive (for use with ASY-RLYCH-xxRL relay chassis only)
KSS-120AC-3AMP Solid-state relay, 120 VAC @ 3 A
KSS-60VDC-3AMP Solid-state relay, 10-60 VDC @ 3 A
KSS-200DC-lAMP Solid-state relay, 200 VDC @ l A
KSD-A12DC-10A Electromechanical relay, SPST, Form A, 120 VAC @ 10 A, resistive
Cable connecting cam modules to relay chassis (8 outputs per cable):
CBL-RLYCH-DA4 15-conductor cable, with overall foil shield, 4 ft length and sub D connector on both ends,
for interconnection of relay chassis to the PLS
CBL-RLYCH-D04 15-conductor cable, with overall foil shield, 4 ft length and sub D connector on one end and
open on the other, for interconnection of relay chassis to the PLS cam module
CL-15S22-DAxxx Same as above with extended lengths. xxx = length in ft., 010, 025, 050, and
50 ft. increments, e.g., 100, 150, 200 ft., etc.
Brake Input to the PLS Relay:
ASY-BRAKE-RLY Relay including socket required to wire brake input to the PLS, 120 VAC coil

5. MINI•PLS with Built-in Power Relay Output Chassis,, Back-Panel, or Nema 12 (IP52) Enclosure Mounting

Select appropriate system:
SAC-MX1-X2 X3 MINI•PLS system for back-panel mounting with cam modules, power output chassis, and relays
    X1 = Basic Model:
            1250: The M1250 MINI•PLS
            1450: The M1450 MINI•PLS
            1451: The M1451 Mini•PLS
    X2 = Type of power relay outputs:  
            16RL: 16 electromechanical relay outputs, 120 VAC @ 10 A
            16AC: 16 solid-state AC relay outputs, 120 VAC @ 3 A
            16DC: 16 solid-state DC relay outputs, 9-60 VDC @ 3 A
            16AD: 8 solid-state AC relays, 120 VAC @ 3 A and 8 solid-state DC relays, 9-60 VDC @ 3 A
            32RL: 32 EM-relay outputs, 120 VAC @ 10 A
            32AC: 32 solid-state AC relay outputs, 120 VAC @ 3 A
            32DC: 32 solid-state DC relay outputs, 9-60 VDC @ 3 A
            40RL: 40 EM-relay outputs, 120 VAC @ 10 A
            40AC: 40 solid-state AC relay outputs, 120 VAC @ 3 A
            40DC: 40 solid-state DC relay outputs, 9-60 VDC @ 3A
    X3 = Type of MINI•PLS:
            0: 3-digit, single-turn rotary PLS (model M1250)
            1: 3-digit, single-turn rotary PLS with ModZ and speed compensation (model M1450-300)
            2: 3-digit, single-turn rotary PLS with multiple rate offsets model M1450-MROF)
            3: 4-digit, single-turn rotary PLS with ModZ and speed compensation (model M1450-400)
            4: 6-digit, multi-turn, single resolver linear PLS (model M1450-M10)
            5: 6-digit, 64:1 ratio, multi-turn linear PLS (model M1450-D64)
            6: 6-digit, 128:1 ratio, multi-turn linear PLS (model M1450-D128)
            7: 6-digit, linear PLS (model M1450-LTO)
            8: 3-digit, single-turn rotary PLS with ModZ/Brake Monitor, speed compensation, and serial communication capabilities (model M1451-010)
Select part number of output chassis for back panel mount unit only:
(Relays not included, see below to order)
ASY-OUTPT-16RL Chassis for 16 electromechanical, DPDT relay outputs
ASY-OUTPT-16SS Chassis for 16 solid-state relay outputs
ASY-OUTPT-16RS Chassis for 8 electromechanical DPDT relay and 8 solid-state relay outputs
Select type and number of output relays: (Required for ASY-OUTPT-xxxx relay chassis)
KDD-012DC-10SIG 10 A (any VAC as long as does not exceed 10 A) DPDT electromechanical relay
KSS-120AC-ERI 3 A, 120 VAC, solid-state AC relay module
KSS-055DC-ERI 2 A, 3-40 VDC, solid-state DC relay module
KSS-AC/DC-ERI Low leakage (<0.1 mA), AC/DC solid-state relay module, 135 VAC (rms) @ 0.35 A
or 190 VDC (max.) @ 0.5 A
Select appropriate enclosure, if required:
ENC-M1250-N16 NEMA 12 (IP52) enclosure for 16-channel PLS
ENC-M1250-W16 Above enclosure with see-through window
ENC-M1250-N32 NEMA 12 (IP52) enclosure for 32-channel PLS
ENC-M1250-W32 Above enclosure with see-through window
ENC-M1250-N40 NEMA 12 (IP52) enclosure for 40-channel PLS
Spare Parts:
EEC-15PIN-0TB 15-position terminal block for main terminal block on M1250 and for cam modules
EEC-18PIN-0TB 18-position Main terminal block for M1450/M1451
MCP-M1250-011 Cover plate for unoccupied cam module space
ECM-15PIN-M11 15-Pin sub D male connector
CBL-M1250-INPUT M1250 to main terminal block connector for back panel mounted systems
CBL-M1250-OUTPUT M1250/M1450 to output chassis for back panel mount systems
CBL-M1450-INPUT M1450 to main terminal block connector for back panel mounted systems

Home | About Us | Support | Downloads | Free Catalogs | Contact

Copyright © 2014 Autotech Controls. All rights reserved. All Product names, trademarks and registered trademarks are the property of their respective manufacturers or legal holders. Autotech Controls disclaims any proprietary interest in the marks or names of others. All prices are US List prices and are subject to change without notice.