AVG Autotech Controls

Autotech Controls HomeAbout Autotech ControlsSupportDownloadsFree CatalogsContact Autotech Controls

M1950-P10 Specifications

1.   I2 PLS
SAC-M1950-010 Base unit to support PLS, Die Protection and Tonnage at Angle modules
SAC-M1950-01A Same as above plus supports Shut Height
Slave Units: S: For a slave M1950 change the A in SAC (in above part number to S

24VAC/220V/240 VAC Units

2: For 220/240 VAC, 50/60 Hz AC power input on above chassis, change the C in SAC to 2
4: For 24 VAC power input change the C in SAC in above part number to 4
2. Plug-in Modules
Maximum of five (5) modules in any combination
ASY-M1950-16x PLS output module – 16 channels
ASY-M1950-DPx Die Protect Module for up to 8 inputs
ASY-M1950-PEK2x Programmable Load (Peak Tonnage) Monitor with 2 channels (can only be used with SAC-M1950-0-A
AXY-M1950-RAx Tonnage at Angle Module for up to 4 sensors (Sensors are not included), see step 6)
ASY-M1950-RSHIx Resolver (multi-turn) based, absolute, shut-height indication module with 2 programmable limit outputs (Requires (1) SAC-RL210-G128M resolver and cable)
ASY-M1950-RSHCx Resolver (multi-turn) based, absolute, shut-height control module, consisting of 1 power output chassis, interconnecting cable (4 ft.), 8 relays, 1 SAC-210-G128M resolver (resolver cable is not included)
Where x = P: PNP Sourcing Outputs
N: NPN Sinking Outputs
*Consult factory for availability
3. Remote Power Relay Output Chassis
3.1 Select relay chassis part number. Must use PNP type of output module (see step 2). Relays not included, see step 3.2 below to order.
ASY-RLYCH-08SS Chassis for 8 solid-state relay outputs or electro-mechanical SPST outputs using KSD-A12DC-10AMP relays
ASY-RLYCH-16SS Chassis for 16 solid state or electro-mechanical SPST (KSD-A12DC-10A SPDT relay)
ASY-RLYCH-08RL Relay chassis with 8 electro-mechanical SPDT outputs (Use only KSD-012DC-10A SPDT relay)
ASY-RLYCH-16RL Relay chassis with 16 electro-mechanical SPDT outputs (use only KSD-012DC-10A SPDT relay)
220V/240 VAC Units For 220/240 VAC, 50/60 Hz AC power input on above chassis, change the Y in ASY to 2

Home | About Us | Support | Downloads | Free Catalogs | Contact

Copyright © 2014 Autotech Controls. All rights reserved. All Product names, trademarks and registered trademarks are the property of their respective manufacturers or legal holders. Autotech Controls disclaims any proprietary interest in the marks or names of others. All prices are US List prices and are subject to change without notice.