M1950-P10 Specifications
1. I2 PLS
|
||
SAC-M1950-010
|
Base unit to support
PLS, Die Protection and Tonnage at Angle modules
|
|
SAC-M1950-01A
|
Same as above plus
supports Shut Height
|
|
Slave Units:
|
S:
|
For a slave M1950 change
the A in SAC (in above part
number to S
|
24VAC/220V/240 VAC Units
|
||
2:
|
For 220/240 VAC, 50/60
Hz AC power input on above chassis, change the C in SAC to 2
|
|
4:
|
For 24 VAC power input
change the C in SAC in
above part number to 4
|
|
2. Plug-in Modules
|
||
Maximum of five (5)
modules in any combination
|
||
ASY-M1950-16x
|
PLS output module – 16 channels
|
|
ASY-M1950-DPx
|
Die Protect Module for
up to 8 inputs
|
|
ASY-M1950-PEK2x
|
Programmable Load (Peak
Tonnage) Monitor with 2 channels (can only be used with SAC-M1950-0-A
|
|
AXY-M1950-RAx
|
Tonnage at Angle Module
for up to 4 sensors (Sensors are not included), see step 6)
|
|
ASY-M1950-RSHIx
|
Resolver (multi-turn)
based, absolute, shut-height indication module with 2 programmable limit
outputs (Requires (1) SAC-RL210-G128M resolver and cable)
|
|
ASY-M1950-RSHCx
|
Resolver (multi-turn)
based, absolute, shut-height control module, consisting of 1 power output
chassis, interconnecting cable (4 ft.), 8 relays, 1 SAC-210-G128M resolver (resolver
cable is not included)
|
|
Where x =
|
P:
|
PNP Sourcing Outputs
|
N:
|
NPN Sinking Outputs
|
|
*Consult factory for
availability
|
||
3. Remote Power Relay
Output Chassis
|
||
3.1 Select relay chassis
part number. Must use PNP type of output module (see step 2). Relays not included,
see step 3.2 below to order.
|
||
ASY-RLYCH-08SS
|
Chassis for 8
solid-state relay outputs or electro-mechanical SPST outputs using
KSD-A12DC-10AMP relays
|
|
ASY-RLYCH-16SS
|
Chassis for 16 solid
state or electro-mechanical SPST (KSD-A12DC-10A SPDT relay)
|
|
ASY-RLYCH-08RL
|
Relay chassis with 8
electro-mechanical SPDT outputs (Use only KSD-012DC-10A SPDT relay)
|
|
ASY-RLYCH-16RL
|
Relay chassis with 16
electro-mechanical SPDT outputs (use only KSD-012DC-10A SPDT relay)
|
|
220V/240 VAC Units
|
For 220/240 VAC, 50/60 Hz
AC power input on above chassis, change the Y in ASY to 2
|