GENERAL:
Power Requirements:
120VAC+/- 10%, 50-60 Hz., 24VA
240VAC+/- 10%, 50-60 Hz., 24VA
(Optional)
Operating Temperature:
-10°F to 130°F (-23°C to 55°C)
Position Transducer:
Single turn resolver such as RL100;
with CBL-10T22-Mxxx cable, 2,500 ft. max.
Supervisory, Brake Input and Brake Reset Inputs:
Optically isolated
TRUE: Contact closure to VS- (common)
FALSE: Open circuit
Motion Detector & Brake Monitor
Motion Detector Limits:
2, Low & High. programmable; Motion detector
output energizes when the resolver RPM is
between low and high limits.
Brake Monitor:
Normally energized, de-energizes when press
stopping time (0-9.99 sec) exceeds programmed
danger limit - 2nd caution output energized
when stopping time exceeds caution limit.
Brake Input:
Brake timing starts when the input becomes TRUE.
# of PLS Programs/Set-ups:
up to 100, keypad selectable
Scale factor: Programmable 16-999
Offset:
Programmable from 0-Scale
Factor, common to all programs
PLS Module
Scan Time:
100-280 microseconds
No of PLS outputs:
16 per module, optically isolated,
“P” or “N” factory ordered
Die Protection Module
Number of inputs:
8, optically isolated; all inputs “P”
type or “N” type, factory ordered
Event Detection:
Programmable rising edge, falling edge
or pulse detection within programmed window.
Fault Outputs:
All outputs either “P” or “N” type (see GENERAL
section), factory ordered Faults because of the
non-occurrence of event can be assigned
to activate one of the two outputs:
Top Stop: Stops press at top
E-Stop:
To stop press immediately
2 Pre-set Counters:
Outputs energize at 0 count
|
|
Shut Height Module
Position Transducer:
RL210, 128:1 geared Dual Resolver
Outputs:
Outputs to motorized slide adjust
to move in Up and Down directions.
Peak Load Monitor Module
Load Sensor:
AVG-Autotech’s Load Sensor with
built-in electronics to provide
4-20mA current signal
Number of Sensors:
4 per module
Outputs:
4 to detect Positive & Negative tonnage
press limits, Over & Under Die Limits
Tonnage at Angle
Load Sensor:
AVG-Autotech’s Load Sensor with built-in
electronics to provide 4-20mA current signal
Number of Sensors: 4 per module
Outputs: All outputs “P” or “N” type, factory ordered
Press Safe:
Normally energized; de-energized when peak tons
exceed programmed max. limit
Die Safe:
Normally energized, de-energized when acquired
tonnage profile lies outside the programmed
band around stored reference profile
QC Alarm:
Energized when number of bad parts exceed
programmed limit (a part is considered bad if
acquired tonnage profile is
outside programmed QC band)
Serial Communication:
(Required for tonnage
signature on PC)
RS485 multi-drop
Remote Power Relay Outputs
All modules with NPN sinking output can use
remote power relay chassis to provide higher
power outputs. The relay supported are
electromechanical (10A@120VAC),
AC solid-state (3A@24-280VAC) and DC
solid-state (3A@9-60VDC or 1A@0-200VDC). |