AVG Autotech Controls

Autotech Controls HomeAbout Autotech ControlsSupportDownloadsFree CatalogsContact Autotech Controls

M8350 Resolver Decoder BusModule Specifications

ASY-M8350-010


A complete functional Decoder consists of a Cradle (specific to the programmable controller type), a Decoder Module (ASY-M8350-01 0), and a Filler Module (ASY-M8250-FIL). If fault and/or motion outputs need to be directly wired to field devices, an output module (such as, ASY-M8250-XOUT) must be used in place of the filler module. Consult Autotech for specifications on output module. 
Card Location:  Uses one or two slots (any location) in an
     1/0 rack. 
PLC Communication:  Command-based communication
     using standard program controller logic. 
Power Requirements:  
Backplane:  5 VDC @ 650mA 
Customer (Input Power):  24 VDC ± 100mA 
Environment Conditions:  
Operating Temperature:  -10°F to +130ºF (-23ºC to
     +55ºC) 
Relative Humidity:
  5 to 95% non-condensing

RESOLVER INTERFACE:
Position Transducer:  Autotech's series RL 100, E7R,
     E8R, or RLI 01, RL500 or equivalent resolvers. 
Cable Length between Resolver and M8350:  2500 feet
     max, shielded. 
Resolver Cable:  Overall foil shielded, twisted pair, such as
     Autotech's cable (CBL-1 OT22-xxxx).

PROGRAMMING:
All features programmable from keypad or through
     backplane. 
Scale Factor:  Programmable from 19 to 4095 (Resolution
     20-4096 counts per turn).

 

Offset:  Programmable from 0 to scale factor value.

OUTPUTS:
RPM Format:  Binary
Fault Detector:  -TRUE (active) on power-up -FALSE if
     broken resolver wire or internal fault is detected.
Motion Detector:  -Low and high motion limits are
     programmable from 0 to 1999 RPM -motion detector is
     TRUE when the machine's RPM is within the
     programmed limits motion detector's status is available
     on the backplane.
Direction:  CW (clockwise) or CCW (counterclockwise)
     indication. On is CCW, Off is CW.

RESPONSE TIMES:
Tach Update Time:  15ms
Position, Tach and Output Status available to
     Backplane:
  Every 700 ps typical

CONTROL INPUTS:
Program Enable (PE):  PE must be TRUE for
     programming.

ELECTRICAL SPECIFICATIONS:
Optical Isolation:  2500 VAC RMS
Input Current:  3 mA typical @ 24 VDC
Logic Levels:  -TRUE: 21 to 27 VDC (not to exceed V+
     relative to V-) -FALSE:< 1 VDC

Home | About Us | Support | Downloads | Free Catalogs | Contact

Copyright © 2014 Autotech Controls. All rights reserved. All Product names, trademarks and registered trademarks are the property of their respective manufacturers or legal holders. Autotech Controls disclaims any proprietary interest in the marks or names of others. All prices are US List prices and are subject to change without notice.